DC Output:
              
              
                Output power:
Configurable as 400 kW, 300 kW, or 200 kW
Upgradable from 200 kW to 300 kW or 400 kW
Dynamic Power Sharing: 50 kW power granularity
Output voltage: 150 - 980 V
Output current (peak): CCS1/2: 600 A; J3400: 375 A
Number of outlets: dual outlet
Power conversion efficiency: up to 97%
              
             
                      
              
                AC Input:
              
              
                Nominal voltage: (CE): 400 Vac (NA): 480 Vac
Nominal input current (RMS): A200: (CE): 306 A (NA): 255 A
A300: (CE): 460 A (NA): 383 A | A400: (CE): 612 A (NA): 510 A
Frequency: (CE): 50 - 60 Hz (± 5%) (NA): 60 Hz (± 5%)
Earthing systems: (CE): TN-C, TN-C-S, TN-S, TT (NA): WYE
Inlet cable size per phase (no neutral): max. 2 x 300 mm2 (600 kcmil)
Power factor: > 0.99 at full load
Total Harmonic Distortion (THD): < 3%
Overvoltage category: III
SPD: (CE): Type 1 + 2 (NA): Type 1
SCCR: (CE): 50 kA (NA): 65 kA
              
             
          
         
              
                      
              
                Operating Conditions:
              
              
                Operating from -30°C to 55°C (-22°F to 131°F) with derating
Storage from 5°C to 40°C (41°F to 104°F), IEC 60721-3-2
Altitude: 2000 m (6562 ft)
Humidity: up to 95%, non-condensing
Impact resistance: IK10 (A400 display: IK08 until Q3 2025), NEMA 3R
IP rating: IP54, indoor and outdoor rated
Noise emission average within 1 m radius, at 25°C (77°F), full power:
A200: 62 dB(A) | A300: 64 dB(A) | A400: 65 dB(A)
Intended use: indoor and outdoor
Mounting options: floor mounted
Environment pollution degree: Class 3 (outside), Class 2 (inside)
              
             
                      
              
                Form Factor:
              
              
                Dimensions of charger body (H x W x D):
2256 x 790 x 810 mm (88.8 x 31.1 x 31.9 in)
Weight: A200: 560 kg (1235 lbs) | A300: 645 kg (1422 lbs)
A400: 730 kg (1610 lbs)
Accessibility: meets ADA requirements for height, reach,
and user interface. DIN 18040 (for A400 coming Q3 2025)
Enclosure type: high-durability aluminum body
Corrosion resistance: C5-H, ISO 12944
              
             
          
         
              
                      
              
                Display:
              
              
                Type: 32” HD full-color anti-glare LCD; Brightness: 1300 nits
Contrast: 5000:1; Interface: 4 push buttons
              
             
                      
              
                Lighting:
              
              
                Roof: 360° dual RGBW LED strips; Gun holder: RGBW LEDs
              
             
                      
              
                Languages:
              
              
                English, French, Spanish, German, Italian, Norwegian, Dutch
              
             
                      
              
                Connector Options:
              
              
                CCS1/2 with patented two-phase cooling technology
J3400 air-cooled
              
             
                      
              
                Cable Management System (CMS):
              
              
                2 x integrated self-retracting swing arm
              
             
                      
              
                Cable:
              
              
                Length: 4.8 m (15.7 ft); Reach: 3.5 m (11.4 ft)
Length: 7 m (22.9 ft); Reach: 6.3 m (20.7 ft)
Type: Air-cooled
              
             
                      
              
                Authentication Methods:
              
              
                RFID, Autocharge, Plug & Charge, credit/debit card, mobile app
              
             
                      
              
                RFID System:
              
              
                Mifare ISO 14443 A/B to part 4 and ISO 15693,
ISO 18092/ECMA-340 (NFC). Others available on request
(Calypso, Ultralight, PayPass, HID, and more)
              
             
                      
              
                Remote Management:
              
              
                Access control, configuration, diagnostics, software updates
              
             
          
         
              
                      
              
                Safety Standards:
              
              
                (CE): IEC 61851-1, IEC 61851-23
(NA): UL 2202, UL 2231-1, UL 2231-2, CSA 22.2 No.346:22
              
             
                      
              
                Metering:
              
              
                (CE): Eichrecht (NA): CTEP/NTEP
              
             
                      
              
                EMC:
              
              
                (CE): IEC 61851-21-2 (NA): FCC 47 CFR Part 15B (Class A)
              
             
                      
              
                Manufactured:
              
              
                USA & Europe
              
             
                      
              
                Network Connections:
              
              
                3G/4G/5G, Ethernet (10/100 Base-T), optional second modem
(coming Q3 2025)
              
             
                      
              
                Network Communication Protocol:
              
              
                Open Charge Point Protocol (OCPP) 1.6J and 2.0.1
              
             
                      
              
                Vehicle Communication Protocol:
              
              
                DIN SPEC 70121, ISO 15118-2, ISO 15118-3, Autocharge,
Plug & Charge
              
             
                      
              
                RED Directive:
              
              
                ETSI EN 300 330, ETSI EN 301 489-1, ETSI EN 301 489-3,
ETSI 301 489-52, ETSI EN 301 908-13, EN 50364 (RFID),
IEC 62311: 2019, EN IEC 62311: 2020 (4G test)
              
             
                      
              
                Additional Standards:
              
              
                DC Vehicle connector compliant with IEC 62196-1, IEC 62196-3,
Cabinet IP rating according to IEC 60529
              
             
                      
              
                Designed Lifespan:
              
              
                10 years